Roof Cowls – OMNIE Underfloor Heating, Heat Pumps & Ventilation
We - and our partners - use cookies to deliver our services and personalise your experience. By using our website, you agree to the use of cookies as described in our Cookie Policy.
×
Get a Quote
OMNIE for Developers
System Design
Underfloor Heating
Underfloor Heating
Why UFH?
Explore the Range
Floating Floors
Floating Floors
FoilFloat
LowBoard
Back
Batten Floors
Batten Floors
FoilBatten
TorFloor
Back
Suspended Floors
Suspended Floors
FoilBoard
TorFloor
Underplate
Back
Screeded Floors
Screeded Floors
ScreedPlate
ScreedPlate Compact
Staple
Back
Acoustic Floors
Acoustic Floors
New Acoustic Range
TorFloor RdB
LowBoard RdB
Back
Low Build Up
Low Build Up
LowBoard
TileOver Ultimate
Back
Manifolds & Pipe
Manifolds & Pipe
Precision-Flo Manifold
OMNIFLO Pipe
FORMUFLO Pipe
Back
Back
Heat Pumps
Ventilation & Heat Recovery
Controls
Technical Support
Technical Support
Datasheets & Guides
FAQs
Support Hub
Tile Adhesives Calculator
Back
Technical Resources
Case Studies
Get in touch
Book a RIBA CPD Course
About OMNIE
Call us today 01392 36 36 05
Home | Resources
Roof Cowls
All

Roof Cowls

DS MVHR 09

UB41

 

This UB41 unit comprises a flat box hood on a circular up-stand, a 500 x 500mm lead flashing skirt and stepped adaptor which allows connections from 100mm to 160mm diameter ducting. All cowls and external grilles for ventilation should have a minimum separation of 1500mm-2000mm. In some circumstances this is not possible and can be reduced down to 300mm to meet building regulations.

Cowl – min 22 deg pitch / (150mm / 125mm connector) HR155 / CQ350

1. 150mm Comfo Pipe
2. 150mm Comfo Pipe collar
3. 90 deg 150mm elbow
4. UB41

The free vent areas and pressure/airflow resistance readings for the UB41 are below.

In instances where the CQ450 and CQ600 are used we have 2 x UB41 for the fresh air, and 2 x UB41 for the exhaust. The main duct-work uses a Y splitter from the 180mm duct-work to 2 x 150mm to provide the correct flow rate.

Diameter (mm)Free vent (mm2)Pressure/AirflowPressure/Airflow
Resistance (100m3/h)(Pascals) (225m3/h)
1007,8503.07.5
1108,8504.516.0
12512,2505.324.0
15017,7756.531.0

OTF4A

 

Flat roof.

Min 300mm distance between fresh air exhaust. Both Cowling’s must be fitted on the same elevation or roof pitch.