OMNIE Precision-Flo Manifold
Manifold with Circulator and mixing unit |
---|
Sizes available 2 to 12 Port Suitable for: Water, Water/Glycol mixtures Temperature Range: -10°C to +95°C Motor design: A-rated circulator Max system pressure: 6 bar Electrical supply: 200-240 Volt, 50/60 Hertz Power consumption: 3-45 Watt Watt protection: IP 44 Insulation class: F 3 way thermostat & mixing valve: Size 1 – Range of regulation 25-55°C Manifold with mixing unit The manifold is supplied with a mixing unit and circulator to ensure the water temperature entering the floor does not exceed the design temperature. This manifold configuration is essential if the heat source is able to supply high temperature water. The circulator comes pre-set to recommended settings.
|
Circulator User Manual | ||
---|---|---|
WILO - Circulator User Manual - Download
|
LOWARA - Circulator User Manual - Download
|
STUART TURNER - Circulator User Manual - Download
|
Circulator Troubleshooting guide |
---|
Wilo - Circulator Troubleshooting guide - Download
|
ST - Circulator Datasheet |
---|
ST - OEM-2560-130-Circulator Datasheet - Download
|
Branch Only manifold |
---|
Optional ‘Branch’ manifold: If the water is supplied at the correct temperature then the mixing valve is unnecessary. Also, if there is a primary circulator installed then this can be removed from the manifold assembly too. |
Dimensions | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pump/Mix & Pump Only Unit: Width = Measured left to right, this includes the pump and mixing pack. The Pump only arrangement is identical in size but without the mixing element. Height = Measured from bottom of isolation valves to top of flow meters (allow space for pipes to bend into the floor). Depth = Measured from wall. this is 200mm which is indicative (always allow space for sufficient working access) Arms Only Unit: Width = Measured left to right, this includes the isolation valves (you will need to allow space for Flow & Return pipework and sufficient working access) Height = Measured from bottom of wall bracket to top of flow meters (allow space for pipes to bend into the floor). Depth = Measured from wall. this is 150mm which is indicative (always allow space for sufficient working access) Note: When installing/locating the manifold, you must always allow space for Flow & Return pipework and sufficient working access. |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|