Hot & Cold Manifold Distribution - OMNIE Underfloor Heating, Heat Pumps & Ventilation
We - and our partners - use cookies to deliver our services and personalise your experience. By using our website, you agree to the use of cookies as described in our Cookie Policy.
×
Get a Quote
Technical Information
Technical Information
Datasheets & Install Guides
Install Videos
UFH Performance Label
Parts Guide
FAQs
Back
Knowledge Guides
UNDERFLOOR HEATING
UNDERFLOOR HEATING
Why Underfloor Heating?
Choose by Floor Finish
Timber Structural
Timber Structural
Why TorFloor® 2
TorFloor® 2 Standard
TorFloor® 2 Plus
TorFloor® 2 RdB (Acoustic)
Installation Guide
Installation Video
AL HEX Foil Diffusers
Back
Overlay
Overlay
Why LowBoard® 2
LowBoard® 2 Standard
LowBoard® 2 Plus
Installation Guide
Installation Video
AL HEX Foil Diffusers
Ultimate 2
Back
Floating & InterJoist
Floating & InterJoist
FoilBoard
FoilBatten25/50
FoilFloat25
AL HEX Foil Diffusers
Back
In-Screed
In-Screed
Staple
Back
Acoustic & Specialist
Acoustic & Specialist
OMNIE-TILE
ACOUSTIC
ACOUSTIC
For Joisted/Batten Floors
Back
Back
Manifolds & Pipe
Manifolds & Pipe
Precision-Flo Manifold
OMNIFLO Pipe
FORMUFLO Pipe
Back
Back
SMART CONTROLS
SMART CONTROLS
OMNIE Smart Thermostat
OMNIE App & Gateway
Back
OMNIE for Developers
Contact Us
Aftersales Support
Smart Controls Support
Case Studies
Sales 01392 36 36 05 Service & Parts 01392 36 36 05

Hot & Cold Manifold Distribution

Simplify your hot & cold water distribution.

Hot & cold water that is distributed from a manifold improves installation time, reduces dependency on fittings and allows easy isolation of independent elements.

Key Benefits

Provides you with individual isolation of outlets and appliances if required. You are able to isolate parts of the system whilst the rest remains operational, reducing disruption for installation and maintenance.

Reduced installation time of between 30%-40% due to fewer fittings required.

Gives you a reduction of up to 70% of joints, with virtual elimination of tees and elbows, therefore the chance of leaks both during and post installation is greatly reduced.

Ensures that you have good accessibility in the event of a problem - limits the points at which a leak could occur to the point of use and the manifold, significantly reducing the time for fault finding.

All joints are above ground and are easily accessible.

Monoblocco connectors allow you to tailor the outlet sizes for different pipe sizes going to different outlets. You can therefore optimise the pipe size to be installed per outlet.

Allows you to adjust the flow rates to individual outlets.

Allows an easier understanding of water system schematics in relation to points of isolation. This will ensure future maintenance and repair can be carried out with minimum disruption.

Isolation and Maintenance

Manifold distribution provides total or individual isolation to all hot water and cold water points in the building, with the ability to isolate parts of the system whilst the rest remains operational therefore reducing disruption for installation and maintenance.

Manifolds can be installed in a convenient accessible location(s).

Distribution Manifolds

Nickel plated extruded brass manifold with colour coded isolating valves designed plumbing systems to minimise joints and leaks.

Available in ¾” single rails from 2 ways to 12 ways and can isolate individual circuits.
Can be mounted offset one above the other, side by side or upside down, using single or double mounting brackets or slider rail plug-in system.
Can be surface mounted, concealed in a purpose designed plastic cabinet or within a partition wall.

Red and blue outlet identification labels are supplied which can be marked to indicate which outlet they are serving for ease of maintenance.

The manifolds are supplied as single rails for flexibility in mounting and installation with a slider rail system, enabling the rails to be mounted either offset above one another or side by side.

Pipes are connected using monoblocco fittings.

Maximum operating pressure: 10 bar
Maximum operating temperature: 110 °C

Pre-insulated Pipe

The pipe comes fully insulated and colour coded (red for hot, blue for cold), this padding will also reduce the risk of noise from the water supply network.

Pipe routes can be planned in advance and once securely fastened in place they are basically maintenance free, no intermediate fittings to worry about, only fittings at either end which remain accessible with the pipe runs being fully insulated. The water is also protected against temperature loss for the hot and gain for the cold.

WRAS approved
Cross-linked polyethylene inner pipe (PE-Xb).
Bonding layer connecting the inner pipe to the aluminium pipe.
Butt-welded aluminium pipe, thickness min 0,2 mm.
Bonding layer connecting the outer pipe to the aluminium pipe.
Cross-linked polyethylene outer pipe (PE-Xb).

OUR PRODUCTS
  • Underfloor Heating
  • Smart Controls
  • Case Studies
  • Product Guide
USEFUL INFORMATION
  • General Product Warranties
  • Heat Pump System Warranty
  • Returns Policy
  • Website Usage Terms & Conditions
  • Privacy & Cookie Policy
  • Terms & Conditions of Sale
  • OMNIE Home Smartphone App EULA & Privacy Policy
  • Apply for a credit account
FOLLOW US
  • Connect with us on LinkedIn
  • omnieUFH Follow us on Facebook
  • @OMNIE_UK Watch on YouTube
  • @omnie_uk See us on Instagram
  • @omnie_uk Keep in the loop on TikTok

Copyright OMNIE 2024 - OMNIE is a trading name of Genuit UFH Limited. Registered in England and Wales No.15733512 Registered Office: 4 Victoria Place, Holbeck, Leeds, England, LS11 5AE